We are all over the world

As NextArray continues to grow and expand our footprint across the world continues to grow. We have listened to our clients and when requested have made ever effort to expand with their needs. Looking for a location not yet on our map? Contact us today and add your spot to the NextArray world map.

It all starts with the right location.

Finding the right location for you and your business is key when it comes to hosting. That is why we provide some of the best locations in the industry all across the United States. NextArray wanted to bring our clients the possiblity to host anywhere. Contact us today to learn more.

NextArray - Central

01

Dallas, TX. (Infomart)

N+1 UPS redundant, 6.66 MW critical load UPS capacity, 150+ W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 2.0 PUE rating,

02

Port Edwards, WI.

N+1 Power Backup, Uninterruptible Power Supplies (UPS), Diesel Generator Backup, Multiple Internet Service Providers (ISP), Fully Redundant Juniper Connection Switches, Redundant Gigabit Ethernet Links

03

Cincinnati, OH.

N+1 UPS redundancy, 3.80 MW critical load UPS capacity, 150 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.6 PUE rating

04

Louisville, KY.

2N UPS redundancy, 3.09 MW critical load UPS capacity, 150 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.5 PUE rating

05

Minnieapolis, MN.

N+1 UPS redundancy, distributed, redundant4:3 UPS, 9 MW critical load UPS capacity, 1,500 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.4 PUE rating

06

Nashville, TN.

N+1 UPS redundancy, 1.49 MW critical load UPS capacity, 150 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.85 PUE rating

07

San Antonio, TX.

Reliable APC power distribution units (PDU), enterprise grade Powerware uninterruptible power supplies (UPS), and ASCO automatic transfer switches Facility-wide redundancies with maintenance bypasses that ensure continued data availability

NextArray - West Coast

01

Los Angeles, CA.

On-site backup generators, On-site fuel storage, Tier IV Data Center, Remotely Monitored Video Surveillance, SSAE16 Certified, BSOC2 Type II Certified, PCI DSS, HIPPA, 24x7 On-site Security

02

Las Vegas, NV

N+1 UPS redundancy, distributed redundant ,4:3 UPS, 9 MW critical load UPS capacity, 1,500 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.3 PUE rating

03

Portland, OR

N+1 UPS redundancy, 5.30 MW critical load UPS capacity, 300 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.4 PUE rating

04

Denver, CO.

N+1 UPS redundancy, 6.75 MW critical load UPS capacity, 150 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.4 PUE rating

05

Phoniex, AZ.

2(N+1) UPS redundancy, 5.02 MW critical load UPS capacity, 180 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.6 PUE rating

06

Salt Lake City, UT

N+1 UPS redundancy, 2.65 MW critical load UPS capacity, 240 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.5 PUE rating

NextArray - North East

01

Richmond, VA.

N+1 UPS redundancy, 2.80 MW critical load UPS capacity, 150 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.5 PUE rating

02

Philadelpiha, PA.

2(N+1) UPS redundancy, 7.20 MW critical load UPS capacity, 1,500+ W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA

NextArray - South East

01

Atlanta, GA.

2N UPS redundancy, 6 MW critical load UPS capacity, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.5 PUE

02

Charleotte, NC

N+1 UPS redundancy, 3.3 MW critical load UPS capacity, 150 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA

03

Fort Lauderdale, FL.

N+1 UPS redundancy, 3.15 MW critical load UPS capacity, 150 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.65 PUE rating

04

Jacksonville, FL.

N+1 UPS redundancy, 1.39 MW critical load UPS capacity, 150 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.65 PUE rating

05

Tampa, FL.

2N UPS redundancy, 3 MW critical load UPS capacity, 150 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.75 PUE rating

06

Raleigh, NC.

N+1 UPS redundancy, 4.31 MW critical load UPS capacity, 150 W/SF power density, N+1 cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.4 PUE rating

NextArray - Europe

01

London, UK

UPS redundancy backed by 3 days of diesel generator power for critical load, N+1 underfloor cooling redundancy, Hot/cold aisle configuration, 100% power SLA, 1.85 PUE rating and ISO accredited 9001 to 27001.

02

Frankfurt, DE

Coming Soon!

NextArray - Australia

01

Brisbane, AU

24/7 Australian-Based Support, ISO 27001, PCI-DSS, SOC 1 & 2, Direct Cloud Connect AWS, Google, Azure, DDos Protection Mitigation & Scrubbing Services, Power options from 3kW to 12 kW available, Keyless racks, swipe card racks

02

Perth, AU

Coming Soon!